Ethanol precipitation of DNA sequencing reactions
网站地图本站论坛
高级搜索收藏本站
 
 当前位置:试验方案>核酸试验>DNA试验>基础知识> 正文

Ethanol precipitation of DNA sequencing reactions

点击:   作者:51protocol收集   来源:  时间: 2007-03-25  本站论坛

 

  1. Take the 384 plate from the thermocycler and add 16ul ddH2O (depending on reaction volume) to each well using the Hydra.
  2. Centrifuge to 1000 rpm to force water to the bottom of the well. Briefly vortex the plate with a tight hold to mix sample with the water. Centrifuge again.
  3. Transfer the sample/water mix to a 96 well reaction plate using the Hydra. Add 60ul EtOH/NaOAc (made according to standard protocol) to the 96 well reaction plate using a 12 channel pipet.
  4. Place the 96 well plate in a thermocycle plate base and centrifuge immediately at 3200 rpm, 4degC, for 30 to 40 minutes. Note that this is a room temperature ethanol pptn step with centrifugation at 4degC. Identical results have been obtained with 1:12 diluted big dye reactions followed by precipitation at -20degC. In either case, no 'big-dye blob' at ~140 nucleotides was observed, because of the greatly reduced amounts of big dye in the reaction mixes.
  5. Decant the EtOH/NaOAc. This can be done a couple of ways. One way is turning the plate upside down on a paper towel and patting dry. However, because we all have a tendency to do this with varing degrees of force, a better method is to place upside down on a paper towel in a Beckman CS-6R table top microtiter plate centrifuge and begin to centrifuge. immediately turn the centrifuge off. Once stopped, remove the microtiter plates and place upright on the lab bench. The important part is to get rid of a majority of the EtOH/NaOAc and not lose any sample.
  6. Rince by adding 70ul of 70% EtOH using a 12 channel pipet and centrifuge at 3200 rpm, 4degC, for 10-15 minutes.
  7. Decant the EtOH by placing the plate upside down on a paper towel and centrifuge up to 300 rpm as above and dry in vacuum for 10-15 minutes. The 70% ethanol wash can be repeated prior to drying, but only is necessary if dye blobs are seen during the sequencing run.
  8. Dry the pelleted reaction products in a vacuum for 10-15 minutes.
  9. Dissolve the dryed reaction products in 20 ul of water and load onto the ABI 3700 as recommended. Sit back and enjoy 5 to 10 times higher signal strength.
    ** Note: It is highly likely that a significant amount of the nested fragment set sequencing reaction products are bound to the Sephadex G-50 column because of the slight ionic characteristic of Sephadex when both the column equilibration and DNA elution are done in the presence of water.
version dated 1-24-01
This clearly is an "old procedure revisited" but is extremely efficient because 1) the amount of resulting nested fragment set is at least 5 to 10 times more than obtained by Sephadex G-50 filtration and 2) the signal strength on the ABI 3700 is increased approximately 5 to 10 fold.**

上一篇:Uniplex PCR-based Sequencing   下一篇:Sequencing off Bacterial Genomic DNA with ABI Big Dye Terminators

 
推荐文章
 
相关文章
·Uniplex PCR-based Sequencing
·Sequencing off Bacterial Genomic DNA wit
·Cloning MultiPlex PCR-based Products for
·Large Scale Plasmid, Cosmid, BAC, PAC, a
·Sequencing Reaction Cleanup in 384 Well
·Protocol for Sequencing Very Difficult R
·Quick Isolation of DNA from Agarose Gels
·Cleanup of the 384-well thermocycler pla
·CsCl - density separation of DNA
·Rapid DNA Preparation for Restriction An
·Sequencing-Template Preparation, DS测序
·Obtaining DNA from Agarose Gels (Paper S
·DNA Isolation from Agarose Gels with DEA
·Extraction and PCR Analyis of DNA from M
·Simple Miniprep DNA Preparation
·DNA Isolation from Tails从鼠尾中提取DNA
·Ethanol Precipitation of DNA 乙醇沉淀DNA
·Shorty DNA Prep (per Adam 08/12/04)【Un
·Silinization of Slides硅化玻璃【Harvard
推荐专题


↑返回顶部   打印本页   关闭窗口↓  
 本站申明 联系我们 网站地图
Copyright© 试验方案

Powered by DedeCms email:htmyth#yahoo.com.cn

Optimized to 1024x768 to Firefox,Opera and MS-IE6