Introduction The Bradford protein assay is a simple procedure for determination of protein concentrations in solutions that depends upon the change in absorbance in Coomassie Blue G-250 upon binding of protein (Bradford, Anal. Biochem. 72: 248, 1976). Unlike many other assays, including the Lowry procedure, the Bradford assay is not susceptible to interference by a wide variety of chemicals present in samples. The notable exception is high concentrations of detergents. There is significant protein-to-protein variation in absorbance values obtained with the Bradford procedure and it is advisable to choose a protein standard that is likely to give absorbance values close to those for the protein samples of interest.

The assay here is designed for use in microtiter plates. This is an easy assay format for those with access to multiple channel pipettors and microtiter plate spectrophotometers.

Materials Bradford Reagent - Bio-Rad sells a ready-to-use reagent (cat#500-0006) that can be stored at 4 C. Alternatively, the reagent can be made by dissolving 100 mg Coomassie Blue G-250 (available from several sources) in 50 ml 95% ethanol, adding 100 ml 85% (w/v) phosphoric acid to this solution and diluting the mixture to 1 liter with water.

Bovine serum albumin (BSA) (1 mg/ml) - we dissolve BSA in saline and store it frozen in 1 ml aliquots for quick use. The standard should be dissolved in a buffer similar to that the unknowns will be dissolved in. Note: other standards are acceptable and may be preferred for certain applications (for example, use an IgG standard when measuring concentrations of immunoglobulins.

Microtiter plates - we use Micro Test III Flexible assay plate from Falcon because they are cheap and work well.

Any multi-well microtiter plate reader equipped with a 595 nm filter.

Procedure Note: do all determinations in duplicate or triplicate

1. Pipette 0, 2, 4, 6, 10, 15 and 20 %26micro;l of BSA (1 mg/ml) into assigned wells of a 96-well plate.

2. Pipette up to 20 %26micro;l of unknown samples into individual wells of a 96-well plate.

3. Add 40 ml of Bradford Reagent into all wells containing standard or sample.

4. Add dd H 2O to all wells to bring the final volume to 200 %26micro;l.

5. Read absorbance at 595 nm without any prior incubation.

Representative Standard Curve Note non-linearity at low end of the standard curve

上一篇:LOWRY PROTEIN ASSAY   下一篇:分光光度计测DNA含量的protocol

推荐文章
 
相关文章
·LOWRY PROTEIN ASSAY
·分光光度计测DNA含量的protocol
·数码相机成象原理及专业数码相机的要求
·细说数码变焦
·照相技术原理之一 光的原理
·浅析CCD与CMOS影像感应器的技术原理
·照相机历史之一  百年天塞
·照相机历史之三  早期35mm照相机
·照相机历史之二 Pentax的世界第一
·照相机历史之五 Leica珍藏照相机
·照相机历史之四  Konica单反相机
·照相机历史之六 Leica简史 35mm
·照相机历史之七 Mamiya 120照相
·照相机历史之八 美能达的早期经典相机
·照相机历史之十 CONTAX简史
·照相机历史之十二 话说佳能相机
·照相机历史之十一 话说美能达公司
·CCD图像传感器
·照相机历史之十三 话说尼康公司
推荐专题
 

↑返回顶部   打印本页   关闭窗口↓  
 本站申明 联系我们 网站地图
Copyright© 试验方案

Powered by DedeCms email:htmyth#yahoo.com.cn

Optimized to 1024x768 to Firefox,Opera and MS-IE6